Ramada Plaza Niagara Falls - Indoor Pool west Inspection Results

Directions on Google Maps

Inspection Results - Posted for one year

Nov. 8, 2017
Routine Inspection

Not in Compliance
Total alkalinity was less than 80 mg/L
Every owner and every operator shall ensure that the pool water is treated with chlorine, a chlorine compound or a bromine compound by means of an adjustable dosing device and so maintained that the pH value is within the range of 7.2 to 7.8 the total alkalinity is not less than 80 mg/L.
Not in Compliance
All chemicals were not safely stored or handled
Every owner and every operator shall ensure that, provisions are made for the safe storage and handling of all chemicals required in the pool operation.

Sept. 14, 2017
Routine Inspection

Not in Compliance - Corrected During Inspection
Total alkalinity was less than 80 mg/L
Every owner and every operator shall ensure that the pool water is treated with chlorine, a chlorine compound or a bromine compound by means of an adjustable dosing device and so maintained that the pH value is within the range of 7.2 to 7.8 the total alkalinity is not less than 80 mg/L.
Not in Compliance - Corrected During Inspection
pH was not between 7.2 - 7.8
Every owner and operator shall ensure that the public spa water is treated with chlorine, a chlorine compound or a bromine compound by means of a chemical feeder, and is maintained so that in every part of the spa, and at all times during the daily use period, the pH value is within the range of 7.2 to 7.8.

July 11, 2017
Routine Inspection

Not in Compliance
Manual tests and records were not completed
Daily records are required to be completed ½ hour before opening and every hour while open.
Not in Compliance
Total alkalinity was less than 80 mg/L
Every owner and every operator shall ensure that the pool water is treated with chlorine, a chlorine compound or a bromine compound by means of an adjustable dosing device and so maintained that the pH value is within the range of 7.2 to 7.8 the total alkalinity is not less than 80 mg/L.
Not in Compliance
Daily turnover rate of the water was not maintained at the minimum requirement
Daily turnover rate is the number of times the total volume of water passes through the filter per day.
Not in Compliance
Make-up water was not added and recorded daily
Every operator shall add and record the volume of make-up water added to the pool during each operating day. The amount shall not be less than 20 L per bather per day as determined by a water meter installed for the purpose. Every owner and every operator shall ensure that the clean water and the make-up water are free from contamination that may be injurious to the health of the bathers.

May 10, 2017
Routine Inspection

No Issues Found
No infractions were found at the time of inspection

March 21, 2017
Routine Inspection

Not in Compliance - Corrected During Inspection
Two buoyant throwing aids with rope not provided
Two buoyant throwing aids with rope (6mm diameter, 1/2 width of pool, plus 3m) are available at the pool. (Other than wave action pool)

Feb. 22, 2017
Routine Inspection

Not in Compliance
Manual tests and records were not completed
Daily records are required to be completed ½ hour before opening and every hour while open.