Scott's Trailer Park - Outdoor Pool Inspection Results

Directions on Google Maps

Closures, Convictions and Orders

July 20, 2018
Closure

One of the main drain covers was loose. This may cause injury or trapping of bathers, leading to injury or death.

Inspection Results - Posted for one year

July 20, 2018
Follow-up Inspection

No Issues Found
No infractions were found at the time of inspection

July 20, 2018
Routine Inspection

Not in Compliance
Pool and its equipment are maintained in a safe and sanitary condition.
Not in Compliance
Water meter is provided that registers the volume of all make-up water that is added to the pool

July 20, 2018
Follow-up Inspection

Not in Compliance
Water meter is provided that registers the volume of all make-up water that is added to the pool

June 26, 2018
Follow-up Inspection

Not in Compliance
Daily turnover rate acceptable

June 20, 2018
Routine Inspection

Not in Compliance
pH is within range of 7.2 to 7.8.
Not in Compliance
Total alkalinity is not less than 80mg/L.
Not in Compliance
An adjustable dosing device is used to administer pool sanitizer
Not in Compliance
Daily turnover rate acceptable
Not in Compliance
Markings for water depth, changes and slopes clearly marked on the deck in appropriate locations.
Not in Compliance
Records completed.

Aug. 29, 2017
Routine Inspection

Not in Compliance
Pool and its equipment are maintained in a safe and sanitary condition. .(2)(a)
Not in Compliance
Manual tests and records were not completed
Not in Compliance
Two buoyant throwing aids with rope not provided
Not in Compliance
Spine board not available
Not in Compliance
Written emergency and operational procedures were not provided
Not in Compliance
At the emergency telephone, a notice identifying it as the emergency telephone and listing the names, telephone numbers and addresses of persons who are available for resuscitation, medical aid and fire services or indicating the service to which it is directly connected. R.R.O. 1990, Reg. 565, s. 19 (3).
Not in Compliance
Daily turnover rate of the water was not maintained at the minimum requirement